## Discrepancy

PDIS  641     24-36  2204471  18OCT19  CLT  CLOSE
      BATT 1 OVRTEMP MESSAGE DISPLAYED AND BATT CONTINUES
      TO CLIMB ON GROUND.
FACT  18OCT19  15:34  CLT
            CLEANED AND RESEATED ALL 4 PINS IN BATTERY 1 TEMP SE
            NSOR CONNECTOR (P1007) BATTERY TEMP IS NORMAL WITH NO EICAS MESSAGES. OK FOR SERVICE.
NOTE: ALSO DURING TROUBLE SHOOTING R&R'D BATTERY, TEMP INSTALLED BOTH DAU'S (NO FIX), AND
R&R'D CANNON PLUG ON WIRE P1007 TO BATT #1 TEMP SENSOR.

---