# SDR HNAA2024111801101

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 17, 2024
- Submitted: November 18, 2024
- Operation: Air carrier
- Aircraft: [N932AE](https://openairdocs.org/aircraft/N932AE), registered now
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 14500915
- Aircraft time: 43,838 hours, 39,032 cycles
- System (JASC): [2497 · Electrical Power System Wiring](https://openairdocs.org/jasc/2497)
- Part: Contactor
- Condition: Overheated
- Stage of operation: DE
- How discovered: O
- Nature of condition: M, B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HNAA2024111801101

## Discrepancy

ODOR ON FLIGHT DECK ON DECENT, BECAMRE STRONGER WHEN APU SELCTED.   INSPECTED AND FOUND ODOR TO BE OF A BURNT ELECTRICAL SMELL, VISUALLY INSPECTED LH DISTRIBUTION BOX AND FOUND SEVERAL FUSES AND CONTACTORS K0001 AND K0189 SHOW SIGNS OF OVERHEATING. R&R'D FUSES IAW AMM 20-13-08 AND R&R'D RELAY/CONTACTOR  IAW AMM 20-13-08. OPS CHECK GOOD. OK FOR SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.