# SDR IPXA2026020258624

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 30, 2026
- Submitted: February 2, 2026
- Operation: Air carrier
- Aircraft: [N136UP](https://openairdocs.org/aircraft/N136UP), registered now
- Make and model: Airbus A300 F4-622R
- Registry model: [Airbus A300 F4-622R](https://openairdocs.org/model/airbus-a300-f4-622r) (OpenAirDocs)
- Aircraft serial: 0819
- Aircraft time: 28,574 hours, 17,567 cycles
- System (JASC): [2822 · Fuel Boost Pump](https://openairdocs.org/jasc/2822)
- Part: Pump
- Condition: Failed
- Location: Zone 100
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/IPXA2026020258624

## Discrepancy

CLIMBING THRU FL 300 ALL 4 INNER TANK PUMPS FAILED. DIVERTED TO LOUISVILLE SDF. DEFERRED PER MEL 28-21-09-1. DMP C/W PLACARD INSTALLED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.