# SDR J7SA20120308001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 8, 2012
- Submitted: March 17, 2012
- Operation: Air carrier
- Aircraft: N256FX
- Make and model: Lear 60LEAR
- Aircraft serial: 60257
- Aircraft time: 7,693 hours, 5,346 cycles
- System (JASC): [2613 · Overheat Detection](https://openairdocs.org/jasc/2613)
- Part: Overheat Loop
- Condition: Out Of Position
- Location: Detection Sys
- Stage of operation: CR
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/J7SA20120308001

## Discrepancy

LT AND RT RED BLEED WARNING LIGHTS ILLUMINATED AT FL410. DIVERTED.  REPOSITIONED BLEED DETECT LOOPS IN MULTIPLE PLACES. OPS AND LEAK CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.