## Discrepancy

WHILE IN CRUISE, DIVERTED DUE TO AMBER LT HYD PRESSURE LOW WARNING.  DECLARED AN EMERGENCY AND LANDED WITHOUT FURTHER INCIDENT.  R & R THE LT EDP, THE CASE DRAIN & PRESSURE FILTERS & ALL THREE COUPLING HALVES MM 29-12-01, -15, -19, -23.  OPERATIONS & LEAK CHECKS OF THE LT HYD SYS GOOD.

---