# SDR J7SA20190225001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 25, 2019
- Submitted: March 6, 2019
- Operation: Air carrier
- Aircraft: [N517FX](https://openairdocs.org/aircraft/N517FX), registered now
- Make and model: Bombdr BD1001A10
- Aircraft serial: 20038
- Aircraft time: 13,212 hours, 8,071 cycles
- System (JASC): [2460 · DC Power Distribution System](https://openairdocs.org/jasc/2460)
- Part: Dcpc
- Condition: Malfunctioned
- Location: Electrical Sys
- Stage of operation: CR
- How discovered: O
- Nature of condition: G, H, N
- Precautionary procedure: H
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/J7SA20190225001

## Discrepancy

DIVERTED DUE TO CYAN ELECTRICAL FAULT, WHITE R BATT OFF R GEN OFF. L BATT OFF L GEN OFF. MSG APPEARED IN CRUISE FLT (FL180) TWICE. RESET GENS AND LOST ALL PFD & MFDS. STARTED APU AND LANDED WITHOUT INCIDENT. DOWNLOAD FAULT DATA AND SENT TO FLEXJET. REMOVED LEFT DC POWER CENTER AND INSTALLED MODIFIED DC POWER CENTER. OPS CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.