## Discrepancy

ON APPROACH, WHEN GEAR WAS SELECTED DOWN, RED "ESSENTIAL POWER ONLY" CAS POSTED W/AMBER "R GEN FAIL" AND "R BATT FAIL" CAS POSTED AS WELL AS CYAN "ELECTRICAL FAULT," WHICH TURNED AMBER ON ROLL OUT. R&R LH DC POWER CENTER WITH A MODIFIED LH DCPC OPS CHECK GOOD IAW CL300 AMM 24-61-01. SEE CONTROL SEQUENCE 481930 (SMC) PN OFF AND ON: 975GC02Y06 SN OFF: 468R SN ON: 278R

---