# SDR JJBA20190630020

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 30, 2019
- Submitted: July 2, 2019
- Operation: Air carrier
- Aircraft: [N12160](https://openairdocs.org/aircraft/N12160), registered now
- Make and model: Emb EMB-145XR
- Registry model: [EMB EMB-145XR](https://openairdocs.org/model/embraer-emb-145xr) (OpenAirDocs)
- Aircraft serial: 145799
- Aircraft time: 39,573 hours, 24,925 cycles
- System (JASC): [2131 · Cabin Pressure Controller](https://openairdocs.org/jasc/2131)
- Part: Controller
- Part number: 92185A010200
- Part serial: 00279
- Condition: Inoperative
- Location: Cabin Pressure
- Part time: 3,256 hours, 3,113 cycles
- Stage of operation: CL
- How discovered: O
- Nature of condition: O
- Precautionary procedure: B
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/JJBA20190630020

## Discrepancy

PRESSURIZATION FAILED IN AUTO MODE DURING CLIMB OUT, PRESS MANUAL MODE WORKED FINE. R&R PNEUMATIC OUTFLOW VALVE. OPS CHECK FAILED (PN 2099L011100 SN 02211)R&R ELECTROPNEUMATIC OUTFLOW VALE (PN 2097K011100 SN 00407). OPS CHECK FAILED. R&R DIGITAL AUTO CONTROLLER. OPS CHECK SAT.

---