# SDR JJBA20260312005

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 9, 2026
- Submitted: March 12, 2026
- Operation: Air carrier
- Aircraft: [N11192](https://openairdocs.org/aircraft/N11192), registered now
- Make and model: Emb EMB-145XR
- Registry model: [EMB EMB-145XR](https://openairdocs.org/model/embraer-emb-145xr) (OpenAirDocs)
- Aircraft serial: 14500936
- Aircraft time: 43,086 hours, 28,759 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Valve
- Part number: C1431236
- Part serial: 02022688
- Condition: Inoperative
- Location: Zoen 200
- Part time: 12,350 hours, 10,142 cycles
- Stage of operation: CR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/JJBA20260312005

## Discrepancy

STRONG SMELL OF FUEL IN COCKPIT. PACK 1 RUN COLD AND HOT FOR 1 HOUR. NO FURTHER FUEL ODOR WAS DETECTED. PERFORMED FIM. FOUND AUTO MODE HEAT WORKING INTERMITTENTLY. REMOVED AND REPLACED DUAL TEMPERATURE CONTROL VALVE. LEAK CHECK SAT. OPS CHECK FAILED. REMOVED AND REPLACED RELAY (K0335). OPS CHECK FAILED. PACK 1 OVERHEAT APPEARED ON MANUAL MODE. FOUND LEAKING DUCT ON DUAL TEMP CONTROL VALVE. REMOVED AND REPLACED CLAMPS ON DUEL TEMP CONTROL. OPS/LEAK CHECK SAT. PACK 1 OVERHEAT APPEARS PERFORMING TEST ON MANUAL MODE. OPS CHECK FAILED. REMOVED AND REPLACED TEMP CONTROL MODULE. OPS CHECK FAILED. REMOVED AND REPLACED LH PACK OVERTEMP SWITCH. OPS CHECK FAILED. REMOVED AND REPLACED TEMP CONTROL MODULE. PERFORMED HIGH POWER RUNS. PERFORMED OPS CHECK IN MANUAL AND AUTO. OPS CHECK SAT. NO DEFECTS NOTED AT THIS TIME.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.