# SDR K11A2026030200371

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 2, 2026
- Submitted: March 2, 2026
- Operation: Air carrier
- Aircraft: [N307GT](https://openairdocs.org/aircraft/N307GT), registered now
- Make and model: Boeing 737-3Y0
- Registry model: [Boeing 737-3Y0](https://openairdocs.org/model/boeing-737-3y0) (OpenAirDocs)
- Aircraft serial: 25173
- Aircraft time: 57,072 hours, 40,865 cycles
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Generator
- Condition: Faulted
- Location: Zone 100
- Stage of operation: CL
- How discovered: O
- Nature of condition: H
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/K11A2026030200371

## Discrepancy

NR 2 GENERATOR FAILED AFTER TAKEOFF AT AROUND 6000 FEET. GEN BUS OFF LIGHT ILLUMINATED, PERFORMED GEN BUS OFF LIGHT QRH. AFTER GENERATOR WAS RE ENGAGED GEN BUS OFF LIGHT ILLUMINATED AGAIN, FREQUENCY WAS ZERO VOLTS WERE NORMAL.  TRANSFERRED TO DMI # 33700047 CAT B DUE IN 3 FLIGHT DAYS. IAW B737 KC2 MEL REF 24-1-1B, SPECIAL PROCEDURES 24-01-01B REQUIRED, PLACARDS INSTALLED

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.