# SDR MALA030297

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 8, 2003
- Submitted: June 9, 2003
- Operation: Air carrier
- Aircraft: N514XJ
- Make and model: Bac AVRO146RJ85A
- Aircraft serial: E2330
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Isolation Valve
- Part number: OFFHTE9531101
- Part serial: FRTR010AW
- Condition: Failed
- Location: Hyd System
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/MALA030297

## Discrepancy

DURING CRUISE ON FLIGHT 3548 HYDRAULIC GREEN SYSTEM HI TEMP LIGHT ILLUMINATED.  AIR RETURN TO MEM.  MAINTENANCE REMOVED AND REPLACED GREEN SYSTEM ISOLATION VALVE P/N OFF HTE9531-101, P/N ON HTE9531-3, S/N FRTR010AW.  AMM REF 29-36-00-1 RAN ENGINE NR 3 EDP FOR 40 MINUTES, NO GREEN SYSTEM LIGHT.  LEAK CHECK AND NO LEAKS.

---