# SDR MALA975447

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 30, 1997
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N158MC](https://openairdocs.org/aircraft/N158MC), registered now
- Make and model: Swrngn SA227AC
- Aircraft serial: AC726B
- System (JASC): [2430 · DC Generating System](https://openairdocs.org/jasc/2430)
- Part: Relay
- Part number: A882DL
- Condition: Failed
- Location: Rt Battery
- Stage of operation: CL
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/MALA975447

## Discrepancy

FLT 2931 - OUTBOUND OF MSP, BATTERY FAULT LIGHT AND BOTH RIGHT AND LEFT DISCONNECT LIGHTS ILLUMINATED.  CREW FOLLOWED QUICK REFERENCE HANDBOOK AND COULD NOT RESET.  AIR TURNBACK TO MSP.  MAINTENANCE REPLACED RIGHT BATTERY FAULT TRANSFORMER AND THE SERIES PARALLEL RELAY.  COMPLETED GROUND RUNS.  OPS CHECK GOOD.  REFERENCE MALA975447.

---