# SDR MASA200602193

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 28, 2006
- Submitted: September 1, 2006
- Operation: Air carrier
- Aircraft: [N911FJ](https://openairdocs.org/aircraft/N911FJ), registered now
- Make and model: Cndair CL6002D24
- Aircraft serial: 15011
- Aircraft time: 7,790 hours, 5,524 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Bellows
- Part number: GG43820871
- Condition: Melted
- Location: Rt Pack
- Stage of operation: NR
- How discovered: O
- Nature of condition: B, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/MASA200602193

## Discrepancy

CLT TO DFW - CAPTAIN DECLARED AN EMERGENCY AND DIVERTED TO MEM WHEN AIRCRAFT EXPERIENCED WARNING MESSAGE FOR BOTH THE FWD AND AFT LAV SMOKE DETECTORS AND REPORTED MOMENTARY SMOKE IN THE CABIN.  MX FOUND THE RT PACK CONDENSOR/REHEATER UNIT TUBE BELLOWS MELTED.  PLACED RT PACK ON MEL.  MX R2 HEAT EXCHANGER TUBING.

---