# SDR MEX2002218

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 14, 2002
- Submitted: September 19, 2002
- Operation: Air carrier
- Aircraft: [N505MD](https://openairdocs.org/aircraft/N505MD), registered now
- Make and model: Doug DC-9-82
- Registry model: [Doug DC-9-82](https://openairdocs.org/model/mcdonnell-douglas-dc-9-82) (OpenAirDocs)
- Aircraft serial: 49149
- System (JASC): [3080 · Ice Detection](https://openairdocs.org/jasc/3080)
- Part: Valve
- Part number: 39271012
- Condition: Failed
- Location: Anti Ice Sys
- Part time: 32,744 hours
- Stage of operation: IN
- How discovered: V
- Nature of condition: J
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/MEX2002218

## Discrepancy

FLT 132 - MEX-BJX - WHEN THE ANTI-ICE SYSTEM IS ON, THE LIGHT CABIN FLOW WAS TURNED ON.  AT RON MEX 14/15, IT WAS PERFORMED THE ANTI-ICE TEST IN MODE 1 AND 2.  THE LEFT AUGMENTATION VALVE WAS REPLACED, TESTS OK IAW MM 21-31-021.  (M)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.