# SDR MWEA030421

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 13, 2003
- Submitted: October 13, 2003
- Operation: Air carrier
- Aircraft: [N209ME](https://openairdocs.org/aircraft/N209ME), registered now
- Make and model: Doug DC-9-32
- Registry model: [Doug DC-9-32](https://openairdocs.org/model/mcdonnell-douglas-dc-9-32) (OpenAirDocs)
- Aircraft serial: 47730
- Aircraft time: 52,528 hours, 37,885 cycles
- System (JASC): [2420 · AC Generation System](https://openairdocs.org/jasc/2420)
- Part: Control Panel
- Part number: 914F5655
- Part serial: TZ1750
- Condition: Inoperative
- Location: E/E Bay
- Stage of operation: TX
- How discovered: O
- Nature of condition: J
- Precautionary procedure: D
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/MWEA030421

## Discrepancy

ON START OF RT ENGINE, AC CROSS-TIE LOCK OUT CAME ON, UNABLE TO RESET. REMOVED AND REPLACED AC BUSS CONTROL PANEL.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.