# SDR MYWA110017

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 5, 2011
- Submitted: February 8, 2011
- Operation: Air carrier
- Aircraft: [N752MA](https://openairdocs.org/aircraft/N752MA), registered now
- Make and model: Boeing 737-48E
- Registry model: [Boeing 737-48E](https://openairdocs.org/model/boeing-737-48e) (OpenAirDocs)
- Aircraft serial: 28198
- Aircraft time: 25,045 hours, 24,114 cycles
- System (JASC): [2697 · Fire Protection System Wiring](https://openairdocs.org/jasc/2697)
- Part: Connector
- Condition: Deteriorated
- Location: Fire Loope
- Stage of operation: IN
- How discovered: C
- Nature of condition: L
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/MYWA110017

## Discrepancy

ETOPS SIGNIFICANT SYSTEM:  NR2 ENGINE "A" FIRE LOOP WOULD NOT TEST.  TROUBLE SHOT NR 2 ENG FIRE LOOP FOUND CONNECTOR DS1125 DETERIORATED.  REMOVED & REPLACED IAW M/M 26-11-00.  PERFORMED OPS CHECK IAW MM, OPS CHECKED NORMAL.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.