# SDR N6WA2024072202

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 17, 2024
- Submitted: July 22, 2024
- Operation: Air carrier
- Aircraft: [N524GJ](https://openairdocs.org/aircraft/N524GJ), registered now
- Make and model: Cndair CL6002C11
- Aircraft serial: 10097
- Aircraft time: 43,344 hours, 34,106 cycles
- System (JASC): [2613 · Overheat Detection](https://openairdocs.org/jasc/2613)
- Part: Overheat Loop
- Condition: Out Of Position
- Location: Bleed Leak
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/N6WA2024072202

## Discrepancy

ANTI ICE DUCT WARNING MSG INFLIGHT. FOUND BLEED LEAK DETECTION LOOPS ON MT162 TOUCHING. ADJUSTED LOOPS SPACING IAW CRJ550 AMM36-21-00. OPS AND LEAK CHECKS GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.