# SDR N6WA2026100902

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 4, 2026
- Submitted: October 10, 2026
- Operation: Air carrier
- Aircraft: [N515GJ](https://openairdocs.org/aircraft/N515GJ), registered now
- Make and model: Cndair CL6002C11
- Aircraft serial: 10089
- Aircraft time: 29,512 hours, 28,317 cycles
- System (JASC): [3097 · Ice/Rain Protection System Wiring](https://openairdocs.org/jasc/3097)
- Part: Elec Connector
- Condition: Damaged
- Location: Pitot Heat
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/N6WA2026100902

## Discrepancy

LEFT PITOT HEAT CAUTION MESSAGE AFTER T/O.   REMOVED AND REPLACED LH PITOT PROBE HEATER CONNECTOR IAW ESPM 20-33-00 OPS CHECK GOOD SEALANT NEEDS VERIFIED CURED.

---