# SDR NACA2024122200001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 22, 2024
- Submitted: December 31, 2024
- Operation: Air carrier
- Aircraft: [N563NC](https://openairdocs.org/aircraft/N563NC), registered now
- Make and model: Boeing 767-3BG
- Registry model: [Boeing 767-3BG](https://openairdocs.org/model/boeing-767-3bg) (OpenAirDocs)
- Aircraft serial: 30563
- Aircraft time: 85,132 hours, 21,708 cycles
- Engine: Pwa PW4062
- System (JASC): [7532 · Compressor Bleed Valve](https://openairdocs.org/jasc/7532)
- Part: Isolation Valve
- Part number: 233T32371301
- Part serial: D00919
- Condition: Failed
- Location: Rt Bleed Sys
- Part time: 5,132 hours, 1,681 cycles
- Stage of operation: NR
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/NACA2024122200001

## Discrepancy

RIGHT ISOLATION VALVE SWITCH INDICATES OPEN IN THE OFF POSITION. DEFERRED RH BLEED ISOLATION VALVE PER MEL 36-11-06. REMOVED AND REPLACED BLEED AIR SUPPLY CONTROL PANEL M15 IAW B767 AMM 36-11-26 OPS CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.