# SDR P5CA0300940

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 8, 2003
- Submitted: September 9, 2003
- Operation: Air carrier
- Aircraft: N923FT
- Make and model: Boeing 747-2U3B
- Registry model: [Boeing 747-2U3B](https://openairdocs.org/model/boeing-747-2u3b) (OpenAirDocs)
- Aircraft serial: 22769
- Aircraft time: 75,775 hours, 18,652 cycles
- System (JASC): [2613 · Overheat Detection](https://openairdocs.org/jasc/2613)
- Part: Connector
- Part serial: E
- Condition: Disconnected
- Location: Rt Wing Detector
- Stage of operation: CR
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/P5CA0300940

## Discrepancy

AFT 20 MINUTES INTO CRUISE RT WING L/E OVERHEAT LIGHT ILLUMINATED. REMAINED ON UNTIL BLOCK IN. FOUND NR 3 PYLON DETECTOR S1046 SHORTED. DISCONNECTED S1046. ITEM DEFERRED PER MEL 26-22-03A. SECOND LOOP OPS NRML PER MM 26-15-00

---