# SDR P5CA2015051100040

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 10, 2015
- Submitted: May 12, 2015
- Operation: Air carrier
- Aircraft: N643GT
- Make and model: Boeing 767-3JHF
- Registry model: [Boeing 767-3JHF](https://openairdocs.org/model/boeing-767-3jhf) (OpenAirDocs)
- Aircraft serial: 37809
- Aircraft time: 5,702 hours, 1,550 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Duct
- Condition: Leaking
- Location: Rt A/C Pack
- Stage of operation: NR
- How discovered: 9
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/P5CA2015051100040

## Discrepancy

EICAS MESSAGE "PACK TEMP".  EICAS MESSAGE "R PACK OFF" ACCOMPLISHED PACK TEMP PROCEDURE, STBY AND WORKED FINE, RT PACK RESET.  PNEUMATIC AIR LEAKED FROM RT PACK COMPRESSOR OUTLET DUCT, REINSTALLED RT PACK COMPRESSOR OUTLET DUCT AND LEAKS OK IAW AMM 21-51-23/401.  CLEANED AND REINSTALLED LT OUTLET TEMP SENSOR AND THEN CHECKED OK IAW AMM 21-52-06/401.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.