# SDR P5CA2018100100305

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 1, 2018
- Submitted: October 1, 2018
- Operation: Air carrier
- Aircraft: [N642GT](https://openairdocs.org/aircraft/N642GT), registered now
- Make and model: Boeing 767-3Y0
- Registry model: [Boeing 767-3Y0](https://openairdocs.org/model/boeing-767-3y0) (OpenAirDocs)
- Aircraft serial: 26207
- Aircraft time: 79,045 hours, 20,883 cycles
- System (JASC): [3097 · Ice/Rain Protection System Wiring](https://openairdocs.org/jasc/3097)
- Part: Connector
- Part number: DPX2DA2657533B14
- Condition: Defective
- Location: Window Heat
- Stage of operation: TX
- How discovered: O
- Nature of condition: J
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/P5CA2018100100305

## Discrepancy

REPEAT WRITE UP - ON TAXI IN RT FWD WINDOW EICAS . CW WITH QRH AND MSG CLEARED(<DIV>LOG PAGES 0965135-3, LOG PAGE 0965137-07 AND -08 : TS PER WDM 30-41-012 CW CONTINUITY  CHECKS FROM R1 WINDOW J1,J5,D1914,D1912 TO WINDOW HEAT CONTROLLER AND FROM CONT PANEL TO R1 WINDOW ALL WIRES CHECKED OK SEE LOG PAGE 0965137-7 FOR CORRECTIVE ACTION - REMOVED AND REPLACED CONN D1914 AND D1912 PER WDM 30-41-12 SHT 2 RT FWD WINDOW HEAT OPS CHECKS OK PER AMM 30-41-00. ALSO, REMOVED AND REPLACED CONNECTOR D2898A PER WDM 30-41-12 SHT 2 WINDOW HEAT OPS CHECKS OK PER AMM 30-41-00 (PN DPX2DA-26575-33B-1401) </DIV>)

---