# SDR P5CA2019051500075

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 15, 2019
- Submitted: May 22, 2019
- Operation: Air carrier
- Aircraft: N643GT
- Make and model: Boeing 767-3JHF
- Registry model: [Boeing 767-3JHF](https://openairdocs.org/model/boeing-767-3jhf) (OpenAirDocs)
- Aircraft serial: 37809
- Aircraft time: 14,883 hours, 4,226 cycles
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Shutoff Valve
- Part number: 80217012
- Part serial: 0905074
- Condition: Malfunctioned
- Location: Bleed Air Sys
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/P5CA2019051500075

## Discrepancy

R HPSOV EICAS DURING LEVEL OFF. COMPLIED WITH QRH.  R HPSOV STATUS ON FOR DURATION OF FLIGHT.(<P>BLEED MONITOR SHOW HPSOV WIRE FAULT ITEM DEFER PER MEL 36-11-02-02 CAT C. MDDR 111712.</P><P>REF LOG PAGE 917070 ITEM 4; RIGHT HPSOV REPLACED, LEAK CHECK AND FUNCTIONAL CHECK C/OUT IAW AMM 36-11-07-024-001-001 AND AMM 36-11-07-424-016-001. NIL DEFECTS DMI CLEARED </P><P>REF LOG PAGE 917070 ITEM M5; RIGHT ENGINE HPSOV ELECTRICALLY RE CONNECTED, BONDING CHECK C/OUT, RIGHT ENGINE HPC RE CONNECTED AND AIR SUPPLY MODULE BITE C/OUT PER AMM 36-11-07-024-001-001. ALL OPS SYSTEM INDICATION NORMAL. </P>)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.