# SDR P5CA2019091700184

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 16, 2019
- Submitted: September 18, 2019
- Operation: Air carrier
- Aircraft: N644GT
- Make and model: Boeing 767-3JHF
- Registry model: [Boeing 767-3JHF](https://openairdocs.org/model/boeing-767-3jhf) (OpenAirDocs)
- Aircraft serial: 37810
- Aircraft time: 16,247 hours, 3,920 cycles
- System (JASC): [2163 · Cabin Temperature Sensor](https://openairdocs.org/jasc/2163)
- Part: Filter
- Part number: 215T14182
- Condition: Clogged
- Location: Cockpit Temp
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/P5CA2019091700184

## Discrepancy

AFTER TAKEOFF, FLIGHT DECK AUTO TEMP CONTROLLER WENT FULL COLD. AS PER AMM 21-61-03, ZONE TEMPERATURE CONTROL BITE TEST VERIFIED NO FAULTS. CLEARED FLIGHT DECK TEMPERATURE SENSOR AND BULB PER AMM 21-61-00. FOUND FLIGHT DECK TEMP SENSOR/BULB, FORM FILTER CLOGGED. REMOVED AND REPLACED FILTER AS PER AMM 21-61-09. OPERATIONAL CHECK OF FLIGHT DECK TEMP CONTROL, TEMP CONTROL NORMAL AS PER AMM 21-61-00.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.