# SDR P5CA2020123100412

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 31, 2020
- Submitted: January 4, 2021
- Operation: Air carrier
- Aircraft: N643GT
- Make and model: Boeing 767-3JHF
- Registry model: [Boeing 767-3JHF](https://openairdocs.org/model/boeing-767-3jhf) (OpenAirDocs)
- Aircraft serial: 37809
- Aircraft time: 19,412 hours, 5,221 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Warning Message
- Condition: False Activation
- Location: Lt Pack Temp
- Stage of operation: CR
- How discovered: O
- Nature of condition: N
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/P5CA2020123100412

## Discrepancy

LT PACK TEMP ILLUMINATED IN CRUISE.  PERFORM L PACK TEMPERATURE CONTROLLER BITE TEST AND TEST NORMAL, AS PER AMM 21-51-14.  PERFORMED LT & RT PACK OPERATION CHECK AND AIR COND CHECK NORMAL, AS PER AMM 21-00-00/ 21-51-00.

---