- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 17, 2025
- Submitted: October 17, 2025
- Operation: General aviation
- Filed by: [M1 Support Services, repair station QR9R369D](https://openairdocs.org/faa-repair-station/QR9R369D/m1-support-services.md) (OpenAirDocs)
- Make and model: Bolkms BK117C2
- Aircraft serial: 9790
- Aircraft time: 3,779 hours
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Sensor
- Part number: FSC211
- Part serial: 2018
- Condition: Out Of Limits
- Location: Generator
- Stage of operation: TX
- How discovered: V
- Nature of condition: F
- Precautionary procedure: C
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/QR9R202510170003

## Discrepancy

GEN AMPS INDICATIONS WERE 25-35 OFF OF EACH OTHER. #1 INDICATED 10-15 AMPS, #2 INDICATED 30-40 AMPS. AFTER AVIONICS CYCLED PITOT HEAT ON AND OFF, THE AMPS BEGAN FLUCTUATING 10-20 AMPS EACH. DURING SHUTDOWN AT IDLE THE AMPS INDICATED ONLY 5 AMPS DIFFERENCE. REMOVED AND REPLACED #1 CURRENT SENSOR IAW AMM 24-30-00, 4-6. T/F MOC COMPLETED GOOD.

---