# SDR QR9R2026042900001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 29, 2026
- Submitted: April 29, 2026
- Operation: General aviation
- Filed by: [M1 Support Services, repair station QR9R369D](https://openairdocs.org/faa-repair-station/QR9R369D/m1-support-services.md) (OpenAirDocs)
- Make and model: Bolkms BK117C2
- Aircraft serial: 9708
- Aircraft time: 5,131 hours
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Sensor
- Part number: FSC211
- Part serial: 2885
- Condition: Fluctuates
- Location: Generator
- Stage of operation: TX
- How discovered: O
- Nature of condition: J
- Precautionary procedure: C
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/QR9R2026042900001

## Discrepancy

GENERATOR SPLIT 20 AMPS PRIOR TO TAKEOFF. A TEST PILOT EVAL REVEALED CURRENT SENSOR FAILED OPERATIONAL CHECKS. REMOVED AND REPLACED NR 2 CURRENT SENSOR IAW AMM 24-30-00, 4-6; MOC SUCCESSFULLY COMPLETED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.