# SDR QR9R2026110200001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 2, 2026
- Submitted: November 2, 2026
- Operation: General aviation
- Filed by: [M1 Support Services, repair station QR9R369D](https://openairdocs.org/faa-repair-station/QR9R369D/m1-support-services.md) (OpenAirDocs)
- Make and model: Bolkms BK117C2
- Aircraft serial: 9699
- Aircraft time: 4,810 hours
- System (JASC): [7532 · Compressor Bleed Valve](https://openairdocs.org/jasc/7532)
- Part: Bleed Valve
- Part number: 9550178700
- Part serial: 6121
- Condition: No Indication
- Location: Nr 2 Engine
- Stage of operation: TX
- How discovered: V
- Nature of condition: F
- Precautionary procedure: C
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/QR9R2026110200001

## Discrepancy

#2 BLEED VALVE FLAG NOT INDICATED PRIOR TO TAKEOFF IAW AIRCRAFT CL. A TEST FLIGHT EVAL FOUND #2 BLEED VALVE FLAG FAILED TO APPEAR THROUGHOUT ENGINE START AND GROUND RUN AFTER CLEANING OF BLEED VALVE FILTER. THERE WAS NO INDICATION OF THE BLEED VALVE ON THE VEMD. REMOVED AND REPLACED BLEED VALVE IAW EMM 75-31-00-900-804-A01.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.