# SDR QR9R2026110500001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 5, 2026
- Submitted: November 5, 2026
- Operation: General aviation
- Filed by: [M1 Support Services, repair station QR9R369D](https://openairdocs.org/faa-repair-station/QR9R369D/m1-support-services.md) (OpenAirDocs)
- Make and model: Bolkms BK117C2
- Aircraft serial: 9470
- Aircraft time: 5,442 hours
- System (JASC): [3160 · Central Display](https://openairdocs.org/jasc/3160)
- Part: Display
- Part number: B19030NB05
- Part serial: 7339
- Condition: Faulty
- Location: Zone 200
- Stage of operation: TX
- How discovered: V
- Nature of condition: F
- Precautionary procedure: C
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/QR9R2026110500001

## Discrepancy

#1 GENERATOR AMPS FLUCTUATING, EVEN GOING TO ZERO DURING START RUN-UP. TROUBLESHOOTING FOUND VEMD BAD CAUSING #1 GEN AMP SPLIT. SHOWED 25 AMPS FOR #1 GEN WITH JUST BATTERY ON. REMOVED AND REPLACED VEMD IAW AMM 31-60-00; 4-2. MOC SUCCESSFULLY COMPLETED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.