## Discrepancy

PDX FLIGHT NR 2442 - AFTER PUSH BACK WHEN CONDITION LEVERS WERE BROUGHT UP OUT OF START AND FEATHER, THE NR 2 AC GEN CAUTION LIGHT FAILED TO GO OUT.  THE RAC BUSS CAUTION LIGHT WAS NOTED TO BE ON ALSO.  A BUSS RESET ATTEMPT CAUSED THE RAC BUSS CAUTION LIGHT TO GO OUT BUT NOT THE NR 2 AC GEN CAUTION LIGHT.  MAINTENANCE REMOVED AND REPLACED THE NR 2 AC GENERATOR IAW MTC 6242101.  ALL CHECKS GOOD.  NO LEAKS DETECTED.  NO ABNORMALITIES OBSERVED AFTER THE NR 2 AC GENERATOR WAS REPLACED.  AIRCRAFT RETURNED TO SERVICE.

---