## Discrepancy

RNO FLIGHT NR 2257: AFTER LANDING, NR 3 HYD PUMP CAUTION LIGHT ILLUMINATED.  FOLLOWED E/A CHECKLIST.  LIGHT REMAINED ON.  MAINTENANCE REMOVED AND REPLACED THE HYDRAULIC PUMP IAW 12-01-000-801, 12-01-400-801.  BLED SYSTEM PER 29-10-00-870-803.  OPS CHECK PER 29-12-01-710-801.  RESERVICED NR 3 HYD SYSTEM IAW 12-10-29-611-807.  OPS CHECK AND LEAK CHECK GOOD.  REPLACED RL4 RELAY AS REQUIRED.  AIRCRAFT RETURNED TO SERVICE.

---