## Discrepancy

LAX - NR 1 RUD HYD CAUTION LIGHT ILLUMINATED ON DESCENT INTO LAX.  LANDING UNEVENTFUL.  FERRY TO PDX FOR REPAIRS.  PERFORMED WIRING CHECKS BETWEEN RUD 1 PUSH OFF SWITCH AND FCECU, NO DEFECTS WERE FOUND.  CHECKED WIRING BETWEEN FCECU AND NR 1 RUDDER UNLOAD VALVE AND PCU FOR SHORTS TO SHIELD AND OTHER PINS USING MEGAOHMETER.  NO SHORTS FOUND.  CHECKED WIRING BETWEEN FCECU AND NR 1 RUDDER UNLOAD VALVE AND PCU FOR CONTINUITY USING DIGITAL VOM.  FOUND HIGH RESISTANCE BETWEEN FCECU CONNECTOR 2700-P1 PIN 14 AND NR 1 RUDDER PCU CONNECTOR 2700-P5 PIN 1.  ALL OTHER WIRES CHECK GOOD.  REMOVED CONNECTOR 9811-P891 AND FOUND PIN V OF RECEPTACLE 9811-J891 NOT FULLY SEATED.  PIN V WOULD NOT LOCK IN RECEPTACLE.  REPLACED ELECTRICAL CONNECTOR 9811-J891 IAW DHC-8-400 WDGM 20-17-10.  INSTALLED CONNECTOR 9811-P891.  RESISTANCE CHECK NOW GOOD.  RUDDER CONTROL SYSTEM AND RUDDER CONTROL SHUTOFF VALVES OPERATIONAL CHECK GOOD IAW DHC-8-400 MM TASKS NR'S 27-20-00-710-801 AND 27-20-00-710-802.  ALL INDICATIONS NORMAL DURING TEST.  RETURNED TO SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.