## Discrepancy

DURING CLIMB, NR 1 BLEED HOT CAUTION LIGHT ILLUMINATED. PERFORMED EMERY/ABNORMAL CHECKLISTS. WITH NR 1 BLEED SWITCH OFF, NR 1 BLEED HOT CAUTION REMAINED ILLUMINATED.  REMOVED AND REPLACED NR 1 ENG BLEED OVER TEMPERATURE SWITCH IAW AMM TASK 36-11-16-000-801, AND INSTALLED IAW AMM TASK 36-11-16-400-801. GROUND RAN ACFT, CAUTION LIGHT DID NOT RETURN.  NO OTHER DEFECTS NOTED.

---