# SDR QXEA2009121401037

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 12, 2009
- Submitted: December 14, 2009
- Operation: Air carrier
- Aircraft: N613QX
- Make and model: Cndair CL6002C10
- Aircraft serial: 10045
- Aircraft time: 21,422 hours, 15,800 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Condition: Corroded
- Location: Bs 280
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/QXEA2009121401037

## Discrepancy

C5 CHECK - CORROSION FOUND ON LT AND RT SIDE FS 280.00 BEAM.  DRILLED OUT RT AND LT 280 BEAM FASTENERS IAW SRM 51-42-06-001-001-A01.  PREPARED NEW BEAM IAW REO 670-53-11-047 AND SRM 51-40-11-001-001-A01.  PERFORMED LPI IAW NDTM 51-20-08.  INSTALLED LT AND RT 280 BEAMS IAW REO 670-53-11-047.  TOPCOAT ALL FASTENERS IAW SRM 51-25-00-001-001-A01.  APPLIED CORROSION INHIBITING COMPOUND TO AFFECTED AREA IAW SRM 51-21-11-001-001-A01.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.