# SDR QXEA2011012100062

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 17, 2011
- Submitted: January 21, 2011
- Operation: Air carrier
- Aircraft: [N429QX](https://openairdocs.org/aircraft/N429QX), registered now
- Make and model: Bombdr DHC8402
- Aircraft serial: 4161
- Aircraft time: 9,184 hours, 10,023 cycles
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Shutoff Valve
- Condition: Dirty
- Location: Nacelle
- Stage of operation: NR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/QXEA2011012100062

## Discrepancy

OIL SMELL FROM NR1 BLEEDS WHEN THEY ARE ON.  PERFORMED GVI OF NR1 ENGINE COMPARTMENT, NO DEFECTS NOTED. C/W FIM TASK 71-00-00-810-817, CLEANED NACELLE SHUT-OFF VALVE FILTER IAW AMM TASK 36-11-00-100-801. C/W D8-400-SL-21-012A, GROUND RAN ENGINES SEVERAL TIMES.  NO FURTHER ODORS OR DEFECTS NOTED. ACFT OK FOR CONTINUED SERVICE.  NO PARTS REPLACED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.