# SDR QXEA2013062701133

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 27, 2013
- Submitted: July 3, 2013
- Operation: Air carrier
- Aircraft: N416QX
- Make and model: Bombdr DHC8402
- Aircraft serial: 4083
- Aircraft time: 24,003 hours, 24,498 cycles
- System (JASC): [5210 · Passenger/Crew Doors](https://openairdocs.org/jasc/5210)
- Part: Structure
- Condition: Corroded
- Location: Pax Door
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/QXEA2013062701133

## Discrepancy

FWD PAX DOOR BOTH GOOSENECKS CORRODED.  REMOVED PANELS 131BZ AND 131LZ TO FOM. REMOVED FWD PAX DOOR TO FOM IAW AMM 53-23-01-000-801 AND 52-11-00-000-801, REV 42.  MATCH DRILLED AFT GOOSENECK IAW SRM 51-40-07-02-01, REV.  PRIOR TO MATCH DRILLING FWD AND AFT GOOSENECKS WERE REMOVED IAW AMM 52-11-23-000-801, REV 42.  MATCH DRILLED GOOSENECK IAW SRM 51-40-07-02-01, REV 13. INSTALLED AFT GOOSENECK ON FWD PAX DOOR EXCEPT FOR SEALING IAW AMM 52-11-23-400-801.  INSTALLED FWD GOOSENECK ON FWD PAX DOOR AND SEALED FWD AND AFT GOOSENECK IAW AMM 52-11-23-400-801.  INSTALLED FWD PAX DOOR IAW AMM REV 42 52-11-00-400-801, STEPS 1- 4A4 AND 4A 65) -5E. OPS CHECK SATISFACTORY.  CW PRESSURIZATION AND LEAK CK IAW AMM 21-00-00-863-801, CHECKS GOOD. FWD PAX DOOR INSTALL COMPLETE IAW AMM 52-11-00-400-801, REV 42 PRESSURE LEAK TEST GOOD.  FLOOR PANEL 131CZ CLOSED IN PANEL TALLY BOOK FLOOR PANEL 131BZ WILL BE CLOSED ON NR 800065 WO 125352.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.