# SDR QXEA2016011600030

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 16, 2016
- Submitted: January 20, 2016
- Operation: Air carrier
- Aircraft: N431QX
- Make and model: Bombdr DHC8402
- Aircraft serial: 4164
- Aircraft time: 20,953 hours, 22,456 cycles
- System (JASC): [3040 · Windshield/Door Rain/Ice Removal](https://openairdocs.org/jasc/3040)
- Part: Controller
- Part number: 4100S002002
- Part serial: 0328
- Condition: Failed
- Location: Anti Ice Sys
- Part time: 15,521 hours, 16,622 cycles
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/QXEA2016011600030

## Discrepancy

WINDSHIELD CENTRAL ILLUMINATED, WHEN WINDSHIELD HEAT WAS SELECTED TO NORM. CAPTAIN`S WINDOW WAS COLD.  FO`S WINDOW WAS WARM.  RETURNED TO FIELD.  LANDING UNEVENTFUL.  R & R LT WINDSHIELD ANTI-ICE CONTROLLER IAW AMM TASK 30-41-01-000-801/400-801 SYS OPERATES NORMALLY.  RETURNED TO SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.