## Discrepancy

MULTIPLE BLEED HOT CAUTION LIGHTS ILLUMINATED DURING TAKEOFF ROLL.  OCCURED AROUND 90 KTS.  ABORTED TAKEOFF AND RETURNED TO GATE FOR MAINTENANCE CONTROL.  INTERROGATED CDS IAW AMM TASK 45-00-21-742-801.  NO ASSOCIATED FAULT CODES.  PERFORMED OPS TEST OF THE BLEED AIR SYS IAW AMM TASK 36-11-00-710-802, OPS TEST FAILING AT STEPS 9, 11, 13, AND 23 A/B.  INTERROGATED CDS AFTER PERFORMING OPS TEST, FOUND NO FAULT CODES. C/W OPS TEST OF THE BLEED AIR SYS REF AMM TASK 36-11-00-710-802.  ALL STEPS TEST GOOD.  NO DEFECTS NOTED.  NO ASSOCIATED PRESENT FAULTS FOUND IN CDS.

---