# SDR QXEA2026010500003

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 3, 2026
- Submitted: January 5, 2026
- Operation: Air carrier
- Aircraft: [N658QX](https://openairdocs.org/aircraft/N658QX), registered now
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000945
- Aircraft time: 6,769 hours, 5,510 cycles
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Hydraulic Line
- Part number: 15E0804005
- Condition: Leaking
- Location: Zone 400
- Part time: 6,769 hours, 5,510 cycles
- Stage of operation: AP
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/QXEA2026010500003

## Discrepancy

FLIGHT 2035. ON APPROACH RECEIVED A  HYD 2 LO QTY FOLLOWED BY THE HYD 2 LO PRESS MESSAGE. EMERGENCY DECLARED WITH ATC. LANDED SAFELY AND WAS TOWED INTO THE GATE. NO ADVERSE PASSENGER REACTION. REMOVED FROM SERVICE. REPLACED NR 2 ENGINE DRIVEN HYDRAULIC PUMP.  TIME SINCE NEW 6769 HOURS. DURING CHECKS THE LEAK CONTINUED AND WAS ISOLATED TO A HOSE. BOTH OF THOSE WERE REPLACED. FILTERS FOR THE CASE DRAIN AND THE PRESSURE FILTER WERE REPLACED. CHECKS GOOD AND AIRCRAFT RELEASED FOR SERVICE.

---