# SDR QXEA2026072800168

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 24, 2026
- Submitted: July 29, 2026
- Operation: Air carrier
- Aircraft: [N669QX](https://openairdocs.org/aircraft/N669QX), registered now
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000995
- Aircraft time: 2,859 hours, 2,434 cycles
- System (JASC): [2121 · Air Distribution Fan](https://openairdocs.org/jasc/2121)
- Part: Relay
- Part number: 3283102028VCC
- Condition: Failed
- Location: Zone 100
- Stage of operation: NR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/QXEA2026072800168

## Discrepancy

FLIGHT 2117. RECIRC 2 FAN FAILED.  PLACED ON MEL 21-24-01A. MEL CLEARED BY  CHECKED AND FOUND NO VOLTAGE AT RECIRCULATION FAN 2. REPLACED RELAY K7 IN RIGHT ICC IAW EMBRAER B175 SWPM 20-32-02 PER FIM TASK# 21-24-00-810-802-A. RECIRCULATION AIR SYSTEM OPERATIONAL TEST GOOD IAW EMBRAER 175 MM TASK# 21-24-00-710-801-A. THIS MAINTENANCE ACTION CLEARS MEL 21-24-01(A)

---