# SDR R61A20100074

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 13, 2010
- Submitted: February 16, 2010
- Operation: Air carrier
- Aircraft: N801MA
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000012
- Aircraft time: 15,132 hours, 11,021 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Condition: Corroded
- Location: Fuselage
- Part time: 15,132 hours, 11,021 cycles
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20100074

## Discrepancy

WHILE AC WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON CENTER LT FLOORBEAM AT FR 17.  MAINTENANCE REQUESTED ENGINEERING SUPPORT FROM EMB AND RECEIVED ETD2010-170/01078.  MAINTENANCE REPAIRED PER ETD.  AC STILL OUT OF SERVICE FOR HEAVY CHECK INSPECTION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.