# SDR R61A20100083

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 19, 2010
- Submitted: February 22, 2010
- Operation: Air carrier
- Aircraft: N801MA
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000012
- Aircraft time: 15,132 hours, 11,021 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Doubler
- Part number: 17086657003
- Condition: Corroded
- Location: Fuselage
- Part time: 15,132 hours, 11,021 cycles
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20100083

## Discrepancy

WHILE AC WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON WASTE AND WATER ACCESS STRUCTURE ON FORWARD LOWER CORNER (INTERNAL).  MAINTENANCE REMOVED AND REPLACED DOUBLER STRUCTURE PER EMB SRM.  AC RETURNED TO SERVICE AFTER COMPLETION OF HEAVY CHECK.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.