# SDR R61A20100108

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 8, 2010
- Submitted: March 11, 2010
- Operation: Air carrier
- Aircraft: N816MA
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000037
- Aircraft time: 14,530 hours, 10,467 cycles
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Power Unit
- Condition: Malfunctioned
- Location: Cabin
- Stage of operation: IN
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20100108

## Discrepancy

CREW REPORTED EMERG LIGHT BATT FAULT APPEARS WHEN SWITCH IS IN OFF POSITION.  MAINTENANCE WAS DISPATCHED TO AIRCRAFT TO TROUBLESHOOT, AND PERFORMED ELEC RESET PER EMB AMM OPS CHECK GOOD.  THE SLOT 11 DISCRETE I/O AND SLOT 9 DISCRETE I/O IN SPDA 2 HAVE PREVIOUSLY BEEN REPLACED.  RE335001 ELPU UPGRADE HAS BEEN SCHEDULED BY PLANNING AND WILL BE COMPLIED WITH WHEN PARTS ARE AVAILABLE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.