# SDR R61A20100280

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 26, 2010
- Submitted: June 28, 2010
- Operation: Air carrier
- Aircraft: N816MA
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000037
- Aircraft time: 15,285 hours, 11,100 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Fitting
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20100280

## Discrepancy

WHILE AC WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON SHEAR CLIP AROUND FASTENERS AT FR 85, BY STR 28R.  MAINTENANCE REMOVED AND REPLACED SHEAR CLIP PER THE EMB SRM.  AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.