# SDR R61A20100337

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 15, 2010
- Submitted: July 16, 2010
- Operation: Air carrier
- Aircraft: N868RW
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000131
- Aircraft time: 10,016 hours, 8,582 cycles
- System (JASC): [5210 · Passenger/Crew Doors](https://openairdocs.org/jasc/5210)
- Part: Door
- Condition: Lack Of Lube
- Location: L1
- Stage of operation: UK
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20100337

## Discrepancy

CREW REPORTED L-1 DOOR WAS DIFFICULT TO CLOSE.  MAINTENANCE LUBED THE L-1 DOOR PER EMB AMM, AND OPS CHECK WAS GOOD.  A/C WAS THEN RETURNED TO SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.