# SDR R61A20100393

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 7, 2010
- Submitted: August 9, 2010
- Operation: Air carrier
- Aircraft: N821MD
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000042
- Aircraft time: 15,847 hours, 10,755 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Splice
- Part number: 17086119005
- Condition: Corroded
- Location: Fuselage
- Part time: 15,847 hours, 10,755 cycles
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20100393

## Discrepancy

WHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION AT SUB TOPCOAT CORROSION ON CENTER INTERCOSTAL SPLICE PLATE AT FR 90 FLOORBEAM PAX CABIN.  MAINTENANCE REPLACED THE SPLICE P/N 170-86119-005 IAW EMB 170 SRM.  A/C IS STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.