# SDR R61A20100425

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 30, 2010
- Submitted: September 4, 2010
- Operation: Air carrier
- Aircraft: N871RW
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000140
- Aircraft time: 11,139 hours, 6,621 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Gusset
- Part number: 17060261001
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20100425

## Discrepancy

WHILE THE A/C WAS IN FOR HEAVY CHECK, FOUND LEVEL 2 CORROSION ON THE GUSSET ON FLOORBEAM OUTBOARD OF LT CTR FLOORBEAM AT FR 90.  MX REPLACED THE FLOORBEAM GUSSET IAW EMB 170 SRM.  A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.