# SDR R61A20100426

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 30, 2010
- Submitted: September 4, 2010
- Operation: Air carrier
- Aircraft: N871RW
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000140
- Aircraft time: 11,139 hours, 6,621 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Gusset
- Part number: 17086101001
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20100426

## Discrepancy

WHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON GUSSET ON RT CTR FLOORBEAM BETWEEN FR85 AND FR86.  MX REPLACED THE UPPER SHEET DOUBLER P/N 170-86101-001 ON THE RT CTR FLOORBEAM BETWEEN FR85 AND FR 86 IAW EMB 170 SRM.  A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.