# SDR R61A20100470

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 8, 2010
- Submitted: October 8, 2010
- Operation: Air carrier
- Aircraft: N873RW
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000144
- Aircraft time: 11,534 hours, 6,932 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Part number: 17065669004
- Condition: Corroded
- Location: Fuselage
- Part time: 11,534 hours, 6,932 cycles
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20100470

## Discrepancy

WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE RT FLOORBEAM BETWEEN FRAME 86 & 89.  MAINTENANCE REMOVED AND REPLACED RT FLOORBEAM BETWEEN FRAME 86 & 89 IAW EMB 170 SRM 51-41-01 AND 51-43-01.  A/C IS CURRENTLY STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.