# SDR R61A20100478

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 9, 2010
- Submitted: October 10, 2010
- Operation: Air carrier
- Aircraft: N873RW
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000144
- Aircraft time: 11,554 hours, 6,932 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Part number: 17065669003
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20100478

## Discrepancy

WHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON THE LT FLOORBEAM BETWEEN FR 86-89.  MX REPLACED LT FLOORBEAM IAW EMB 170 SRM 51-41-01, SRM 51-41-03.  A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.